Fast 24 Hour Air Conditioning and Heat Pump Service

Top Quality Workmanship, BBB A+ Rated, AZ ROC Complaint Free

Liebert DS Cooling Configurations

Liebert DS Configuration - UpFlowLiebert DS Cooling Pre-Installation Guidelines

Liebert precision cooling systems are crafted to ensure reliable energy-efficient data center temperature management and more. Yet gaining the benefits of cost-effective data room management demands operative post-installation services. Crafted to contend in all areas of data center efficiency, the Liebert precision line of cooling products includes:

  • Reliable temperature control
  • Efficient cooling racks
  • User-oriented management software
  • Quality surge suppression
  • AND Top-line CRAC cooling units.

Designed to meet and exceed “exact” control room parameters, the Liebert DS cooling system uses advanced dual circuitry that ensures proficient management of airflow, humidity and temperature. It’s a flexible key that assures superior data center performance. When supplemented by the Liebert iCOM control system, the Liebert DS cooling system provides a robust modular-frame solution for data centers and CRAC environments.

But performance is typically defined by the quality of the foundation. When sitting up Liebert DS Cooling configurations, the following Liebert pre-installation guidelines are standard:

  • Proper room preparation
  • Air distribution in downflow units and plenum ducting
  • Air distribution in upflow units
  • Routing for wiring, piping and ductwork as well as other connections and system setup processes
  • Operating conditions
  • The recommended ASHRAE operations envelope defined as defined for data centers in matters concerning cooling, dehumidification and humidification
  • Maximum heating-only temperatures as limited by the qualifications of the Liebert DS.

If the preceding guidelines pop your head full of more questions than answerers, you have come to the right place. Effective CRAC services begin with efficient installation and carry through to reliable system maintenance and services. Rightly configuring your Liebert DS cooling system for optimal performance requires skill, training, and on-the-job know-how. As a world renown leader in manufacture and installation of mission-critical Liebert precision cooling systems and CRAC products, Arizona based American Cooling and Heating can help you get your system up and running quickly and efficiency.

Time Out For Q&A!

For what purpose serves a time delay on an AC unit?

Answer:

When running a single-phase scroll compressor, you may encounter concerns about a pressure-equalization time delay. During off-cycle pressure equalization, scroll compressors spin backwards. Short cycling and energizing a scroll during this time period can cause the unit to continue spinning backwards. Once initiated, this reverse spin will continue until manual ended or the unit trips on internal overloads. Thus may end the life your scroll compressor.

More often than not, a time delay will be linked to anti-short cycling. Short cycling during compressor rush can cause the system to continuously trip a low-pressure safety switch, which in turn can damage the unit. By taking advance of features in a pump down solenoid, some systems isolate refrigerant during off cycling. If the compressor is controlled solely off the LP safety, a faulty LL solenoid can cause pressure to rise in the evaporator during an off cycle. This problem can be present in the recip compressor of an older Liebert Deluxe system.

5 Field Options for Liebert DS Cooling Configurations

1) AIR-COOLED – Liebert DS Cooling Configuration

This process requires piping of field-supplied refrigerant to the condenser. The unit contains a nitrogen holding charge and factory-issued piping is spun closed.

2) GLYCOL-COOLED – Liebert DS Cooling Configuration

Factory charged and confirmed reliable, Glycol-cooled Liebert DS units require field supplied and installed piping from the pump package to the drycooler.

3) GLYCOOL-INTEGRATED FLUID ECONOMIZER – Liebert DS Cooling Configuration

As with the base Glycol-cooled unit, Glycool systems ship factory charged and tested. Piping from the pump package to the drycooler is field supplied and field installed. To complete the installation, cold glycol is circulated through a secondary Liebert Economizer coil that is designed to reduce compressor load when fluid temperatures drop below room temperature.

4) WATER-COOLED – Liebert DS Cooling Configuration

As with the other units, a water-cooled Liebert DS system ships factory charged and factory tested. The piping that runs from the cooling tower to the unit is field supplied and field installed.

5) DUAL-COOL – Liebert DS Cooling Configuration

The dual-cool Liebert DS also incorporates a secondary cooling coil. This unit utilizes access to an external source for chilled water. Cooling is supplemented and improved by circulating chilled water through the secondary coil system.

ACH, Arizona Liebert Precision Cooling Systems

American Cooling and Heating provides full-service installation, repairs and support for Liebert CRAC precision cooling equipment throughout Chandler AZ, Gilbert AZ, Glendale AZ, Mesa AZ, Peoria AZ, Scottsdale AZ, Tempe AZ, And All Other Phoenix Areas.

Please call and direct your questions to our 24-hour service center.

 

air cooled liebert, Liebert DS cooling configuration, Liebert precision cooling


Rm Harrington

About Rm Harrington Professional HVAC content writer, equally skilled for communicating with A/C technicians, HVAC product engineers or the home/business buyer in need of reliable A/C related details. Most valuable skill: The ability to research, comprehend, evaluate and discuss matters of importance to homeowners and the HVAC community, including technical details, system comparisons and best-choice system applications.

Valleywide Service • Fast Response 24/7
Call Now For A Free Estimate

Senior Discounts

Senior Discounts

Payments Accepted

Payments Accepted

BBB A+ Rating

BBB A+ Rating
Complaint Free

Complaint Free

Financing Options

Financing Options

Military Discounts

Military Discounts

Contact Us

American Cooling And Heating
745 N Gilbert Rd 124/276
Gilbert AZ 85234
Phone: (480) 699-2516

Our Reviews

Got a great deal on an AC Trane unit. Needed to get it installed last year when the summer hit. I've had a couple of questions and concerns pop up...

Follow Us


Arizona Air Conditioning Service Center • All Right Reserved ©2020 • AC Service In AZ